Visions PV .018
  • Visions PV .018 digital IVUS catheter provides flexibility for peripheral vessel assessment. The catheter features three 1 mm-long radiopaque markers on the internal lumen positioned 10 mm apart from the distal edge to proximal edge.
  • Product detail photograph
  • Visions PV .018 catheter uses a cylindrical ultrasound transducer array, which radiates acoustic energy into surrounding tissue and detects subsequent echoes. These echoes help generate real-time images of the peripheral vessels.
  • The Visions PV .018 digital IVUS catheter is useful as an adjunctive approach to conventional angiographic procedures, providing clear imaging of vessel lumen and wall structures.
  • Standard product photograph

Visions PV .018

As an adjunct to conventional angiographic interventions, the Visions PV .018 digital IVUS catheter evaluates vascular morphology in blood vessels and provides cross-sectional imaging of these vessels. With a 135 cm working length and 24 mm max imaging diameter for 0.018” guide wire interventional procedures, the device aids in peripheral artery disease diagnosis and guides clinicians toward the correct therapy for the patient’s unique needs.

Clinical image gallery

  • ChromaFlo provides easy assessment of lumen size and stent apposition
    ChromaFlo provides easy assessment of lumen size and stent apposition
Features
ChromaFlo stent apposition assessment
ChromaFlo highlights blood flow red for easy assessment of stent apposition, lumen size, and more. Appropriate for peripheral and coronary vessels, including left main, bifurcations, superficial femoral artery and iliac. It is designed to make lumen size and stent apposition instantly recognizable and helps identify branches, dissections, and plaque in bifurcations.
ChromaFlo
IVUS helps with disease assessment
IVUS imaging helps physicians assess disease markers, including plaque burden percentage, lesion location and morphology, calcium volume, and the presence of thrombus. It also provides analysis of crucial parameters—like luminal cross-sectional measurements—and helps aid in disease diagnosis.
IVUS assesses disease
Helps confirm treatment results
IVUS imaging helps to confirm treatment results, including the completeness of treatment, the apposition and expansion of stent placement, and whether or not the patient requires a thrombolytic drip. ChromaFlo imaging, for example, can be used to show evidence of stent apposition by illustrating the absence of flow.
Treatment outcomes


Specifications
  • Technical Specifications
    Minimum guide catheter
    6 F
    Maximum guide wire
    0.018”
    Maximum imaging diameter
    24 mm
    Working length
    135 cm

Related products

  • Visions PV .035 Digital IVUS catheter
    As an adjunct to conventional angiographic interventions, the Visions PV .035 digital IVUS catheter evaluates vascular morphology in blood vessels and provides cross-sectional imaging of these vessels. With a 90 cm length and 60 mm max imaging diameter for 0.035” guide wire interventional procedures, the device aids in peripheral artery disease diagnosis and venous disease and guides clinicians toward the correct therapy for the patient’s unique needs.